<< Product 12AU7 Vacuum Tube



Classification--It is a Twin triode. It is a nine pins tube.oxide coated cathode of indirect heated.
Application--It intended for use a voltage amplifier or Phase inuerter.
Dimensions--Dimensions, outline diagrams of the tube and bases and the arrangement of electrode commections to the arrangement of electrode connections to the base terminals are shown in Figures 1 and 2 .

Nominal operating conditions and parameters

Heater voltage”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­12.6 V
Heater current”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­..........0.15 A
Plate voltage”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­250 V
Grid voltage”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­.£­8.5 V
Plate resistance”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­7.7 kohms
Plate current”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­10.5 mA
Amplification factor”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­17

Characteristics-Average characteristics

Figure 3. shown typical curves of plate currents as a function of grid voltage for several values of plate voltages.

Fig.3

Limiting Operation Conditions for Safe Nor-nor simultaneous ratings

Maximum plate voltage”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­ 300 V
Maximum Grid voltage”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­-- 50 V
Maximum Grid voltage”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­....0 V
Maximum Power of plate”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­”­2.75 W